Pressure Transmitter, Pressure Switch, Safety Valve & Pressure Relief Design

Pressure safety components protect compressor and pressure vessel from overpressure explosion under abnormal working condition. High pressure switch: cuts compressor power when discharge pressure exceeds limit; trigger by condenser block, fan fault, overcharge. Low pressure switch: suction pressure protection, stop compressor when suction pressure below setting, avoid running under vacuum. Pressure transmitter: convert pressure signal into 4-20mA, feed real-time pressure to PLC controller for remote monitoring. Safety relief valve: installed on receiver, separator; automatically open to release refrigerant when pressure exceeds rated value. Xiteliduo refrigeration receiver is equipped with safety valve as mandatory safety part for export CE audit. Safety valve discharge pipe must lead outside machine room; direct discharge inside closed room brings suffocation and frostbite hazard. Differential pressure switch is used for oil protection; monitor oil pressure difference, alarm and stop when oil pressure insufficient. Pressure switch setting value cannot be modified randomly; setting must comply with local refrigeration safety code. Refrigeration maintenance & repair company verifies high/low pressure action value regularly and records in equipment log.

FAQ

  1. What triggers high pressure switch protection? Excessive discharge pressure.
  2. What triggers low pressure switch protection? Suction pressure too low.
  3. What is the output signal of pressure transmitter? 4–20mA analog signal for PLC.
  4. Where is safety relief valve installed? Liquid receiver and pressure vessel.
  5. Where should safety valve vent pipe discharge to? Outside of machine room.
  6. What is differential pressure oil switch for? Insufficient lubricating oil pressure protection.
  7. Can we adjust pressure switch setting arbitrarily? No, must follow safety standard.
  8. What audit requires safety valve configuration? CE certification for export refrigeration equipment.
Laman sesawang artikel ini: https://ms.xtldcool.com/news/846.html

Dapatkan pelan pengubahsuaian produk dalam talian

Sila isi butiran anda dalam kotak di bawah, dan anda akan dapat memperolehinya secara percuma.

Talian Perunding

+86-18157593311

Xiteliduo & Chuanli

Pabrik Sumber China Kompresor Piston Semi-Hermetik R32 & Sistem Penyejukan Perindustrian Turnkey Tersuai. Kompresor dibangunkan sendiri + penyelesaian penyejukan lengkap, prestasi stabil untuk keadaan kerja tropika & suhu ultra-rendah.

hubungi kami

Perkhidmatan Teknikal: +86-575-83665888;83068555 
Hotline Pemampat: +86-18157593311 
Hotline Tiub Pemanasan Elektrik: +86-13857577938 
Email: helenliu1983xtld@gmail.com 
Kilang Tiub Pemanasan Elektrik: No. 150, Kampung Donghu, Bandar Ganlin, Bandar Shengzhou, Bandar Shaoxing 
Kilang Pemampat: No. 679, Zon Pembangunan Ekonomi Dongguo, Bandar Shengzhou, Bandar Shaoxing

Hak Cipta © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. Semua Hak Terpelihara.